Skip to content

elecdef: design

elecdef defines what electrical and electronic things are: a coil, a contact, a terminal, a connection, a fuse, a power supply, a PLC channel, a conductor, a cable. Each is a block with typed, exact, kind-checked values, its pin markings and its internal links. This file is the current truth of the model; RULES.md is the rule set every change follows.

1. Purpose

elecdef is for every electrical and electronic engineer working in Python: one typed, exact definition of each basic thing in the electrical world, so that nobody types a coil, a contact or a cable again. A parts library describes a real product by filling the blocks' values. An application, a script or a notebook reads the values through one small typed surface. The library judges nothing: it holds facts and looks them up. It has no runtime dependency and runs with or without the rest of the family.

2. The family

Library Owns Never holds
symdef how a thing is drawn: symbols, frames, ports, geometry a rating, a unit, a marking's meaning
elecdef what a thing is: blocks, values, markings, internal links a coordinate, a page, a designation string, a drawing key's meaning
refdef what a thing is called: designations, levels, letter codes, numbering, sort a device fact, a marking's meaning
an application how a project connects, lays out, checks and prints a copy of any fact above

A fact lives in exactly one library. A block names its symbol by a Symbol(key, version) and reads nothing from symdef. A pin marking (13, A1, 95) is an elecdef fact; the string -K1:13 is a refdef fact; which wire lands on it is the application's fact.

3. Core model

3.1 Values

A Quantity is a Decimal and a Unit. A Unit is an enum member carrying a symbol, a Kind (voltage, current, power, apparent power, resistance, frequency, time, length, area, gauge, torque, ratio, temperature, temperature difference) and an exact factor to the kind's base unit. U.V(24), U.MM2("2.5") is the one spelling; a float is refused. == compares as written, same() and ordering compare in base units, to(unit) converts within a kind and refuses across kinds. Percent is a unit of kind ratio. Degrees Celsius and kelvin are different kinds.

A Range is written the way a datasheet states it: a role and up to three ends.

Range(Role.RATED, nom=U.V(24), min=U.V("20.4"), max=U.V(30), at=At(Current.DC))
Range(Role.LIMITING, max=U.V(250))
Range(Role.REFERENCE, min=U.DEG_C(23), max=U.DEG_C(27))

role is positional and required: RATED is what the maker states for the stated conditions, LIMITING is an extreme the thing withstands, REFERENCE is the band other figures are stated for. nom is the marked value; an optional typ holds a measured typical and is never confused with it. tolerance is a property returning exact fractions derived from the ends; it is never written. Every end has one kind. contains(quantity) and covers(range) are the two tests.

At is the set of conditions a figure holds under, one per kind: a Quantity (at 400 V), a Range (up to 250 V), or an enum member (Current.DC, Utilisation.AC_3, CoilState.HOLD, ConductorKind.FINE). A condition's kind is its unit's kind or its enum class. AC and DC are conditions, not fields, so one Ranges field (a tuple of Range) holds the 50 Hz, the 60 Hz and the DC figures side by side.

3.2 Lookup

pick(ranges, *ask) -> Pick(found, issue) returns the single range whose conditions cover the ask. A Range condition covers by inclusion, a Quantity by equality in base units, an enum by identity. A row may state more kinds than the ask names; the ask may not name a kind the row lacks. No covering row gives the issue NO_RATING; more than one gives AMBIGUOUS_RATING; there is no silent first match. This is data access. Whether a load is acceptable against the found range is the application's check, and elecdef stops at found.

3.3 Blocks

A block is a frozen dataclass stating what one kind of thing is. Every property may be unfilled. A property is a Quantity for a dimension or a count-like figure, a Range for an electrical figure, Ranges when it varies with conditions, an enum for a closed vocabulary, int or bool otherwise. Every quantity field declares its kind; a value of another kind is refused at construction. A field that holds a closed set is an enum, never a string.

Blocks compose by typed fields, by value: Relay.coil: Coil, Relay.contacts: tuple[Contact, ...], Coil.connection: Connection. A leaf defined once is passed by reference into every block that has it; equality is by value. elecdef.connections ships technology-only leaves (SCREW, PUSH_IN, ...) with ranges unfilled; a parts library derives its vendor leaves from them with dataclasses.replace and shares those. Family identity of a derived leaf is not tracked. A Connection belongs to the pins a block owns itself: a block that owns pins directly has one connection field (a terminal block has one per side in sides), and a block whose pins all come from its sub-blocks has none. So Coil, Contact, SupplyInput, ChannelGroup, Fuse, FuseHolder, Breaker, Overload, PowerSupply (its output pins), Connector and Device carry one; Relay, Contactor, ContactBlock, PlcCard and Computer carry none.

There is one base class, Block, for mechanism only: it runs the kind check and normalises a bare Range given to a Ranges field. An application never subclasses a block; check reports a block whose class is not in the catalogue. A family template and a product are the same class: the template holds ranges and gaps, the product holds values.

A Pin is (marking, role, side, alternates); a Link is (markings, kind, closed_at_rest), markings a pair, with kind CONDUCTIVE, SWITCHED or PROTECTIVE. Markings follow the block: elecdef.pins derives them by form, index and Marking scheme (AUX n3-n4, n1-n2, n1-n2-n4; MAIN 1/L1-2/T1 ...; OVERLOAD 95-96, 97-98; TIMER n5-n6-n8; PLAIN 1-8) with alternates as data. A composite numbers its unnumbered sub-blocks on every read: a relay's contacts 1..n, a contactor's main poles then its auxiliaries, a contact block from numbered_from, a card's channels across its groups. A product may give pins outright; a coil or contact stores only those and computes the rest, so replace never leaves a stale marking. A composite's pins and links are computed over its sub-blocks and stored nowhere else. A marking is a non-empty string of letters, digits and / + - . ', so every marking reads back unchanged in a designation string such as -K1:13.

3.5 Product

Product(mpn, manufacturer, block, name) is the one identity envelope: a block with its values filled, under a maker's part number. An application wraps it in its own record (suppliers, footprint, class letter) and never copies a block value out of it.

3.6 Issues

check(block | product) -> tuple[Issue, ...] reports content problems as values: an end below another, a marking that repeats, a marking outside the character set, a link naming no pin, a block kind missing a figure it needs, a class outside the catalogue. An Issue is (code: IssueCode, message, subject). IssueCode has eight members: the six that check reports and the two that pick returns (NO_RATING, AMBIGUOUS_RATING). A malformed call (a wrong type, a wrong kind, two conditions of one kind in an At) raises TypeError; content never does.

4. v1 catalogue

Block Reuses States
Body - width, height, depth; ip; temperature (rated, storage); mounting
Connection - technology; conductor area per conductor kind; AWG as stated; conductors per clamp; strip length; torque; screw; pitch; material
Rating - operational voltage per current kind; insulation and impulse voltage; thermal current; current per current kind and conditions; power loss; frequency; overvoltage category; pollution degree
SupplyInput Connection what a powered thing draws: voltage and current per conditions; its supply pins
Contact Connection form (make, break, changeover) and features; switching current per voltage, current kind and utilisation code; limiting voltage per current kind; minimum load; material; life
Coil Connection kind; voltage per current kind and frequency; pick-up and drop-out as ratio; resistance; power and apparent power per coil state; times; suppression; A1-A2
Conductor - material; class; area; insulation; temperature; colour; voltages
Cable Conductor cores (number, colour, pair, drain); screen; armour; diameter; bend radii; sheath; temperature; flags; opaque type code with scheme
TerminalBlock Connection per side, Rating, Body kind; levels with marking and potential; sides; cross-section; width; rail
Relay Coil, Contact, Body kind; contacts; latching; force-guided; timer function
Contactor Coil, Contact, Rating, Body main poles; auxiliaries (a mirror contact is an auxiliary with that feature)
ContactBlock Contact, Body a coil-less carrier: snap-on auxiliary block, button block, limit switch; actuator; first number
Overload Contact, Connection, Body poles; setting; trip class; reset; phase failure; auxiliaries
Fuse, FuseHolder Connection, Rating, Body system; class; current; voltage and breaking capacity per current kind; speed; indicator; poles; disconnect
Breaker Connection, Rating, Contact, Body poles; current; curve; breaking capacities; auxiliaries
PowerSupply SupplyInput, Contact, Connection, Body kind; input; output voltage and current; boost; hold-up; overload behaviour; circuit class; isolation; redundancy; efficiency; OK contact (ok_contact)
Channel, ChannelGroup Connection signal and number; digital input, digital output, analog or relay data; a group's markings, commons, isolation and connection, written once for many channels
PlcCard SupplyInput, ChannelGroup, Body form; role; bus; groups; safety levels
Connector Rating, Connection, Body family; coding; poles; gender; locking
Computer SupplyInput, Connector, Body supply; power; ports
Device Rating, Connection, Body pins and links given outright: the typed fallback for a thing with no block yet

Vocabularies ship as enums in elecdef.vocab: industry codes are the member names (Utilisation.AC_3, FuseClass.gG, TripCurve.C) with short descriptions in our own words. Data tables ship as generated Python in elecdef.tables: the cross-section series, the AWG formula, colour letter codes, the 44-core colour sequence, breaker curve bands, trip classes, cable voltage digits, overvoltage categories, the E series. A table row ships only when its value is confirmed; a contested row waits.

5. Public surface

Top level (elecdef.__all__): Unit, Quantity, Range, Ranges, Role, At, pick, Pick, Issue, IssueCode, check, Symbol, Product, Body, Rating, Connection, Contact, Coil, Relay, Contactor, ContactBlock, Overload, TerminalBlock, Fuse, Breaker, PowerSupply, PlcCard, Device. Twelve doors, each with its own __all__ of the names not exported at top level: elecdef.vocab (Kind and every vocabulary enum), elecdef.pins (Pin, PinRole, Side, Link, LinkKind, Marking and the marking functions), elecdef.connections (SCREW, SPRING_CAGE, PUSH_IN, TENSION, IDC, CRIMP, SOLDER, PRESS_IN, PLUG_IN, BOLT, WIRE_WRAP, THT, SMD), elecdef.tables, elecdef.supply (SupplyInput), elecdef.fuse (FuseHolder), elecdef.plc (Channel, ChannelGroup, DigitalInput, DigitalOutput, AnalogIo), elecdef.terminal (Level), elecdef.conductor (Conductor), elecdef.cable (Cable, Core, TypeCode), elecdef.connector (Connector), elecdef.computer (Computer, Port). The examples in this file assume from elecdef import Unit as U. python -m elecdef api prints every surface name with its signature and docstring; docs/api-snapshot.txt is that output, and a test fails when they differ.

0.2.0 surface (2026-10-23)

Rating.current is the rated current as Ranges, per current kind and conditions: a datasheet states the AC and the DC rating side by side, each with its own conditions. Rating.thermal_current stays beside it, because the thermal current is another datasheet figure and the two are never one fact. Rating.power_loss is the power a part dissipates, one Range with the load in at; several loads are several Ratings. Both new fields follow pollution_degree, so positional calls from 0.1.0 keep their meaning.

Contact.voltage is the limiting voltage as Ranges, per current kind, the same shape as Rating.voltage. A contact has one limiting voltage for alternating current and another for direct current, which one Range cannot say. A bare Range passed in is wrapped into a one-item tuple, so a 0.1.0 call that builds a Contact from one Range still builds. A 0.1.0 reader of contact.voltage.max breaks, and the changelog says so. The supply blocks need no change: a rated 24 V with its operating window is one Range (nom, min, max).

The three needs behind this section are N11 (current as Ranges), N12 (power loss) and N13 (Contact.voltage as Ranges, ruled in for that field only, F12-approved under SPEC-ELECDEF).

6. Out of scope

Checks and judgements (is this load acceptable, is this wire big enough), derating and temperature factors, conductor resistance, cable type-code decoding (the Scheme enum and the opaque TypeCode leave the slot), calculations across blocks, instances and topology, where a pin is wired, drawing, designations and PLC tags, file reading or writing, multilingual names, assemblies of several products. Pilot devices, sensors, motors, passives and semiconductors arrive as blocks after v1; until then they are a Device.

7. Docs and agents

The repository publishes a GitHub Pages site built with Zensical (as symdef does) from the first public release. The site holds this design, the rules, a guide with one runnable example per surface name, and an API reference generated from the docstrings, so a name documented in code is documented on the site by construction. The strict Zensical docs build runs in CI.

llms.txt at the site root lists, in plain text, what the library is, the surface names, the guide pages and the rules, with one link each. AGENTS.md at the repository root tells an agent: read DESIGN.md then RULES.md; read the surface with python -m elecdef api and never the source to use the library; every public name has an example under docs/guide/; the tests named in RULES.md are the definition of done; a change that touches the surface, the design or the rules needs a design review before it is written.

8. How it changes

Semantic versioning. Every surface change carries a changelog line. A pull request that edits DESIGN.md or RULES.md, changes docs/api-snapshot.txt or changes a shipped table under src/elecdef/tables/, carries a Design-review: trailer naming an approved review; a guard script fails it otherwise. An application's missing need is never met by a workaround in the application or a private path into the library: it is a reviewed design change that extends the surface. An application that adopts elecdef shrinks: it deletes its copy of the fact and reads the surface.

Who approves is family rule F12: the maintainer approves the contract, and the design reviewer approves surface and table changes.

9. Licence